Air-circulation Chamber Furnaces up to 850°C
Air-Circulation Bench Type Furnace KU 15/06/A
Air-circulation Chamber Furnaces KU 40/04/A – KU 540/08/A
T max 450 °C, 650 °C and 850 °C
Information
Information
- Air-circulation chamber furnaces up to 850 °C, mainly used for annealing, tempering, ageing, pre-heating, drying, shrinking, baking, testing
- Rugged casing construction made of high-grade steel sheets
- Swinging door hinged on the right
- Inner liner of heat-resistant stainless steel > Long service life, extremely resilient, corrosion resistant
- 2 sheet-metal trays included as standard (KU 15/06/A without trays, for 850 °C models sheet metal trays as option)
- High-grade heating elements with long service life
- Heating from several sides, powerful horizontal air circulation > Excellent temperature uniformity up to +/-3 K in accordance with DIN 17052
- High-grade insulation > Low energy consumption, low operating costs
- Base included in standard supply (KU 15/06/A as bench-type furnace without base)
Options:
- Air circulation furnaces are used for many different applications. The available options meet the specific requirements for the desired heat treatment process. We also supply all furnaces in customized dimensions on request. Automatic exhaust flap control
- Enables exhaust flap to be operated via controller Air extraction
- Ensures fast venting of the furnace chamber Cooling fanFor flushing and for forced cooling of the batch Inert gas connection and sealing
- Prepares furnace for semi-gastight operation Furnace operation with inert gas retort
- Annealing and tempering under inert gas, cooling under inert gas, superb results, bright surfaces almost without oxidation Lift door with pneumatic drive, operated by foot or hand switch Charging supports
- Charging wagon, shown here with a stainless-steel rack, for safe and convenient charging
Technical Data
Technical Data
Model | T max | Inside dimensions | Volume | Outside dimensions | Power | Voltage | Weight |
---|---|---|---|---|---|---|---|
KU 40/04/A | 450 | 300 x 400 x 300 | 35 | 540 x 1050 x 1270 | 3,2 | 230 1/N | 115 |
KU 70/04/A | 450 | 350 x 500 x 400 | 70 | 590 x 1150 x 1370 | 6,4 | 400 3/N | 130 |
KU 140/04/A | 450 | 450 x 600 x 500 | 135 | 690 x 1250 x 1470 | 9,6 | 400 3/N | 205 |
KU 270/04/A | 450 | 600 x 750 x 600 | 270 | 840 x 1450 x 1620 | 12,8 | 400 3/N | 370 |
KU 540/04/A | 450 | 750 x 900 x 800 | 540 | 990 x 1600 x 1820 | 19,2 | 400 3/N | 540 |
|
|
|
|
|
|
|
|
KU 15/06/A | 650 | 300 x 350 x 150 | 15 | 500 x 900 x 440 | 2,4 | 230 1/N | 50 |
KU 40/06/A | 650 | 300 x 400 x 300 | 35 | 540 x 1050 x 1270 | 4,0 | 400 3/N | 125 |
KU 70/06/A | 650 | 350 x 500 x 400 | 70 | 590 x 1150 x 1370 | 8,0 | 400 3/N | 140 |
KU 140/06/A | 650 | 450 x 600 x 500 | 135 | 690 x 1250 x 1470 | 12,0 | 400 3/N | 220 |
KU 270/06/A | 650 | 600 x 750 x 600 | 270 | 830 x 1560 x 1610 | 16,0 | 400 3/N | 390 |
KU 540/06/A | 650 | 750 x 900 x 800 | 540 | 990 x 1600 x 1820 | 24,0 | 400 3/N | 560 |
|
|
|
|
|
|
|
|
KU 40/08/A | 850 | 300 x 400 x 300 | 35 | 850 x 1360 x 1470 | 6,0 | 400 3/N | 290 |
KU 70/08/A | 850 | 350 x 500 x 400 | 70 | 900 x 1460 x 1570 | 10,0 | 400 3/N | 360 |
KU 140/08/A | 850 | 450 x 600 x 500 | 135 | 1000 x 1560 x 1670 | 14,0 | 400 3/N | 580 |
KU 270/08/A | 850 | 600 x 750 x 600 | 270 | 1150 x 1710 x 1770 | 20,0 | 400 3/N | 770 |
KU 540/08/A | 850 | 750 x 900 x 800 | 540 | 1300 x 1860 x 1970 | 30,0 | 400 3/N | 920 |
Air-circulation Chamber Furnaces up to 850°C
Air-circulation Chamber Furnaces
KM 1000/06/A - KM 2000/08/A
T max 650 °C and 850 °C
Information
Information
- Air-circulation chamber furnaces designed for heavy industrial applications with charging weights of more than several tonnes
- Rugged casing construction made of high-grade steel sheets
- Standard furnace door designed as hinged door
- Inner liner of heat-resistant stainless steel > Long service life, extremely resilient, corrosion resistant
- High-grade heating elements with long service life
- Heating from several sides, powerful horizontal air circulation > Excellent temperature uniformity up to +/-7 K in accordance with DIN 17052
- Optimal air circulation by means of air outlets, adapted to the charge
- High-grade insulation > Low energy consumption, low operating costs
Options:
- Hydraulic lifting door
- Automatic control of exhaust flaps
- Powerful cooling system
- Furnace in semi-gastight version with inert-gas connection for operation with protective gases
- Customised designs made to order
Gallery
Technical Data
Technical Data
Model | T max | Inside dimensions | Volume | Outside dimensions | Power | Voltage | Weight |
---|---|---|---|---|---|---|---|
KM 1000/06/A | 650 | 1000 x 1000 x 1000 | 1000 | 2300 x 2100 x 3200 | 36 | 400 3/N | 1300 |
KM 1500/06/A | 650 | 1500 x 1000 x 1000 | 1500 | 2800 x 2100 x 3200 | 48 | 400 3/N | 1500 |
KM 2000/06/A | 650 | 2000 x 1000 x 1000 | 2000 | 3400 x 2100 x 3200 | 72 | 400 3/N | 1750 |
|
|
|
|
|
|
|
|
KM 1000/08/A | 850 | 1000 x 1000 x 1000 | 1000 | 2400 x 2200 x 3300 | 42 | 400 3/N | 1300 |
KM 1500/08/A | 850 | 1500 x 1000 x 1000 | 1500 | 2900 x 2200 x 3300 | 54 | 400 3/N | 1500 |
KM 2000/08/A | 850 | 2000 x 1000 x 1000 | 2000 | 3500 x 2200 x 3300 | 80 | 400 3/N | 1750 |
(Other sizes on request)