en
fr
Contact

Air-circulation Chamber Furnaces up to 850°C

Air-Circulation Bench Type Furnace KU 15/06/A
Air-circulation Chamber Furnaces KU 40/04/A – KU 540/08/A
T max 450 °C, 650 °C and 850 °C

Information

Information

KU 15/06/A
KU 15/06/A
KU 40/04/A
KU 40/04/A
  • Air-circulation chamber furnaces up to 850 °C, mainly used for annealing, tempering, ageing, pre-heating, drying, shrinking, baking, testing
  • Rugged casing construction made of high-grade steel sheets
  • Swinging door hinged on the right
  • Inner liner of heat-resistant stainless steel > Long service life, extremely resilient, corrosion resistant
  • 2 sheet-metal trays included as standard (KU 15/06/A without trays, for 850 °C models sheet metal trays as option)
  • High-grade heating elements with long service life
  • Heating from several sides, powerful horizontal air circulation > Excellent temperature uniformity up to +/-3 K in accordance with DIN 17052
  • High-grade insulation > Low energy consumption, low operating costs
  • Base included in standard supply (KU 15/06/A as bench-type furnace without base)

Options:

  • Air circulation furnaces are used for many different applications. The available options meet the specific requirements for the desired heat treatment process. We also supply all furnaces in customized dimensions on request. Automatic exhaust flap control
  • Enables exhaust flap to be operated via controller Air extraction
  • Ensures fast venting of the furnace chamber Cooling fanFor flushing and for forced cooling of the batch Inert gas connection and sealing
  • Prepares furnace for semi-gastight operation Furnace operation with inert gas retort
  • Annealing and tempering under inert gas, cooling under inert gas, superb results, bright surfaces almost without oxidation Lift door with pneumatic drive, operated by foot or hand switch Charging supports
  • Charging wagon, shown here with a stainless-steel rack, for safe and convenient charging

Technical Data

Technical Data

Model

T max
[°C]

Inside dimensions
[mm]
[width x depthx height]

Volume
[l]

Outside dimensions
[mm]
[width x depth x height]

Power
[kW]

Voltage
[V]

Weight
[kg]

KU 40/04/A

450

300 x 400 x 300

35

540 x 1050 x 1270

3,2

230 1/N

115

KU 70/04/A

450

350 x 500 x 400

70

590 x 1150 x 1370

6,4

400 3/N

130

KU 140/04/A

450

450 x 600 x 500

135

690 x 1250 x 1470

9,6

400 3/N

205

KU 270/04/A

450

600 x 750 x 600

270

840 x 1450 x 1620

12,8

400 3/N

370

KU 540/04/A

450

750 x 900 x 800

540

990 x 1600 x 1820

19,2

400 3/N

540

 

 

 

 

 

 

 

 

KU 15/06/A

650

300 x 350 x 150

15

500 x 900 x 440

2,4

230 1/N

50

KU 40/06/A

650

300 x 400 x 300

35

540 x 1050 x 1270

4,0

400 3/N

125

KU 70/06/A

650

350 x 500 x 400

70

590 x 1150 x 1370

8,0

400 3/N

140

KU 140/06/A

650

450 x 600 x 500

135

690 x 1250 x 1470

12,0

400 3/N

220

KU 270/06/A

650

600 x 750 x 600

270

830 x 1560 x 1610

16,0

400 3/N

390

KU 540/06/A

650

750 x 900 x 800

540

990 x 1600 x 1820

24,0

400 3/N

560

 

 

 

 

 

 

 

 

KU 40/08/A

850

300 x 400 x 300

35

850 x 1360 x 1470

6,0

400 3/N

290

KU 70/08/A

850

350 x 500 x 400

70

900 x 1460 x 1570

10,0

400 3/N

360

KU 140/08/A

850

450 x 600 x 500

135

1000 x 1560 x 1670

14,0

400 3/N

580

KU 270/08/A

850

600 x 750 x 600

270

1150 x 1710 x 1770

20,0

400 3/N

770

KU 540/08/A

850

750 x 900 x 800

540

1300 x 1860 x 1970

30,0

400 3/N

920


Air-circulation Chamber Furnaces up to 850°C

Air-circulation Chamber Furnaces
KM 1000/06/A - KM 2000/08/A
T max 650 °C and 850 °C

Information

Information

need text
need text
need text
need text
  • Air-circulation chamber furnaces designed for heavy industrial applications with charging weights of more than several tonnes
  • Rugged casing construction made of high-grade steel sheets
  • Standard furnace door designed as hinged door
  • Inner liner of heat-resistant stainless steel > Long service life, extremely resilient, corrosion resistant
  • High-grade heating elements with long service life
  • Heating from several sides, powerful horizontal air circulation > Excellent temperature uniformity up to +/-7 K in accordance with DIN 17052
  • Optimal air circulation by means of air outlets, adapted to the charge
  • High-grade insulation > Low energy consumption, low operating costs

Options:

  • Hydraulic lifting door
  • Automatic control of exhaust flaps
  • Powerful cooling system
  • Furnace in semi-gastight version with inert-gas connection for operation with protective gases
  • Customised designs made to order

Gallery

Gallery

need text
need text
need text
need text
need text
need text
need text
need text
KM 2000/06/A - Chamber furnace with hydraulic lift door
KM 2000/06/A - Chamber furnace with hydraulic lift door

Technical Data

Technical Data

Model

T max
[°C]

Inside dimensions
[mm]
[width x depth x height]

Volume
[l]

Outside dimensions
[mm]
[width x depth x height]

Power
[kW]

Voltage
[V]

Weight
[kg]

KM 1000/06/A

650

1000 x 1000 x 1000

1000

2300 x 2100 x 3200

36

400 3/N

1300

KM 1500/06/A

650

1500 x 1000 x 1000

1500

2800 x 2100 x 3200

48

400 3/N

1500

KM 2000/06/A

650

2000 x 1000 x 1000

2000

3400 x 2100 x 3200

72

400 3/N

1750

 

 

 

 

 

 

 

 

KM 1000/08/A

850

1000 x 1000 x 1000

1000

2400 x 2200 x 3300

42

400 3/N

1300

KM 1500/08/A

850

1500 x 1000 x 1000

1500

2900 x 2200 x 3300

54

400 3/N

1500

KM 2000/08/A

850

2000 x 1000 x 1000

2000

3500 x 2200 x 3300

80

400 3/N

1750

(Other sizes on request)