Chamber furnaces
Bench Type Furnaces KM 10/13 - KM 30/13
Chamber Furnaces KM 50/13 - KM 90/13
T max 1300°C
Information
Information
- Double lined housing with rear ventilation > Very low outer casing temperature
- Outer casing side walls and door made of stainless steel > Corrosion resistant
- Lintel of the door also made of stainless steel
- Downwards moving door
- Stainless steel charging support on the door frame
- Exhaust pipe in rear wall
- Base included in standard supply (from model KM 50/13)
- Multilayer insulation (fire bricks and rear insulation) > Low heat loss, very low energy consumption, low operating costs
- High quality heating elements, securely fixed on tubes
- Heated from 3-sides (left, right and bottom) > Excellent temperature uniformity in the chamber
- Heating elements wound on ceramic tubes (from model KM 50/13) > Free heat radiation into the chamber, low energy consumption, longer service life for heating elements
- Bottom heating elements covered by silicon carbide plates > High mechanical strength, protection for bottom heating elements
- Furnaces offer sufficient power > Short heating-up times
- Door safety switch
Technical Data
Technical Data
Model | T max | Inside dimensions | Volume | Outside dimensions | Power | Voltage | Weight |
---|---|---|---|---|---|---|---|
KM 10/13 | 1300 | 250x250x120 | 8 | 500x600x700 | 2,5 | 230 1/N | 75 |
KM 15/13 | 1300 | 250x250x200 | 13 | 500x700x700 | 3,6 | 230 1/N | 85 |
KM 20/13 | 1300 | 250x350x200 | 18 | 500x700x700 | 6,0 | 400 3/N | 85 |
KM 30/13 | 1300 | 250x500x200 | 25 | 500x850x700 | 7,0 | 400 3/N | 95 |
|
|
|
|
|
|
|
|
KM 50/13 | 1300 | 350x500x250 | 44 | 1000x1300x1400 | 13 | 400 3/N | 250 |
KM 70/13 | 1300 | 350x750x250 | 66 | 1000x1400x1400 | 20 | 400 3/N | 330 |
KM 90/13 | 1300 | 350x1000x250 | 88 | 1000x2000x1400 | 22 | 400 3/N | 500 |
Chamber furnaces
KM 105/13 - KM1400/13
T max 1280°C
Information
Information
- Rugged furnace housing made of construction steel, frame welded with steel profiles, covered by metal sheet profiles
- Double lined housing with rear ventilation > Very low outer casing temperature
- Vertical lifting door, from Model KM 2100/13 incl. hydraulic drive
- Door collar made from strong refractory concrete > Resistant to mechanical damages
- Exhaust pipe in rear wall
- Base included in standard supply
- Multilayer insulation (fire bricks and rear insulation) > Low heat loss, very low energy consumption, low operating costs
- Heated from 3-sides (left, right and bottom) > Excellent temperature uniformity in the chamber
- High quality heating elements > Long service life
- Side heating elements wound on ceramic tubes > Free heat radiation into the chamber, low energy consumption, longer service life for heating elements
- Bottom heating elements covered by silicon carbide plates > High mechanical strength, protection for bottom heating elements
- Furnaces offer sufficient power > Short heating-up time
- Door safety switch
Options:
- Charging plate: Extra protection for the furnace bottom
- Silicon carbide protective tiles: Protect the side heating elements against mechanical damage
- Lift door: With hydraulic drive, operated by foot or hand switch
- Cooling fan: Provides forced cooling of the batch
- Inert gas connection and sealing: Prepares furnace for semi-gastight operation
Technical Data
Technical Data
Model | T | Inside dimensions | Volume | Outside dimensions | Power | Voltage | Weight |
---|---|---|---|---|---|---|---|
KM 110/13 | 1300 | 500x750x300 | 112 | 1350x1850x1900 | 22 | 400 3/N | 700 |
KM 170/13 | 1300 | 550x750x400 | 165 | 1400x1850x2000 | 30 | 400 3/N | 900 |
KM 340/13 | 1300 | 750x1100x400 | 330 | 1600x2200x2000 | 48 | 400 3/N | 1400 |
KM 670/13 | 1300 | 1000x1300x500 | 650 | 1850x2400x2100 | 70 | 400 3/N | 2200 |